EAN-13 and UPC-A Barcode Size Specifications

At Barcode Bird, we ensure that all EAN-13 and UPC-A barcodes are supplied in the optimal size for retail use. The standard size for retail barcodes is 25.93mm x 37.29mm, also known as 100% Magnification or SC0. This size is the most widely used in retail environments and helps reduce scanning errors.

Included in these dimensions are the “quiet zones” – the white space on either side of the barcode. These quiet zones are critical as they signal to barcode scanners where the barcode starts and ends. If these areas are removed or too small, the barcode will fail to scan.

  • Left quiet zone: 3.63mm
  • Right quiet zone: 2.31mm

Re-sizing Your Barcodes

While the standard 100% magnification works for most use cases, sometimes your packaging may require a resized barcode. GS1 recommends that barcodes be printed within an 80% – 200% magnification range. If your product packaging allows for it, we suggest following this guideline.

If resizing is necessary, here are some important considerations:

  • Barcodes smaller than 80% magnification may fail to pass a barcode verification report, which is required by many large retailers. See Barcode Verification for more details.
  • Barcodes resized too small or printed with low resolution may fail to scan effectively.
  • EPS image files offer the best flexibility for resizing since they retain image quality when scaled up or down.

For resizing, we recommend using software such as Adobe Illustrator or Photoshop. Simply select the entire barcode image and scale it to the desired size. For example, if you need to resize to meet the 80% magnification minimum, scale the image to 80% of its original size, or 82% to account for print inaccuracies. We recommend using the 2450 DPI EPS version for resizing to ensure no quality loss.

Barcode Truncation

Truncation is a common method used to resize barcodes by cutting off a portion from the top of the barcode, creating a more rectangular appearance. For example, a barcode at 100% magnification can be truncated to meet the minimum bar height of 18.28mm when resized to 80%.

While truncation is a safer resizing method compared to distorting the barcode proportions, there are a few considerations:

  • Truncated barcodes (especially on small products like pens or pencils) may scan at the point of sale (POS) but fail barcode verification.
  • Some retailers may reject products with overly truncated barcodes, while others may still accept them.

We recommend checking with your retailers to ensure your barcode resizing meets their specific guidelines to avoid issues.

Magnification Tables

MagnificationBar Width (mm)Bar Height (mm)L Quiet Zone (mm)R Quiet Zone (mm)
80% (SC0)25.0818.282.901.85
85%26.6519.423.091.96
90% (SC1)28.2220.573.272.08
95%29.7821.713.452.19
100% (SC2)31.3522.853.632.31
105%32.9223.993.812.43
110% (SC3)34.4925.143.992.54
115%36.0526.284.172.66
120% (SC4)37.6227.424.362.77
125%39.1928.564.542.89
130%40.7629.714.723.00
135% (SC5)42.3230.854.903.12
140%43.8931.995.083.23
145%45.4633.135.263.35
150% (SC6)47.0334.285.453.47
15548.5935.425.633.58
160%50.1636.565.813.70
165% (SC7)51.7337.705.993.81
170%53.3038.856.173.93
175%54.8639.996.354.04
180%56.4341.136.534.16
185% (SC8)58.0042.276.724.27
190%59.5743.426.904.39
195%61.1344.567.084.50
200% (SC9)62.7045.707.264.62